Network Appliance NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP - NS0-506 FREE EXAM DUMPS QUESTIONS & ANSWERS
Click the Exhibit button.
cl01::> net int show -vserver
svm1
(network interface show)
Logical Status Network
Current Current Is
Vserver Interface Admin/Oper
Address/Mask Node Port Home
----------- --------- ------
---- ------------------ -----
------- ------ ----
svm1
fc_lif1 up/up
20:0b:00:a0:98:4e:ba:14
cl01-01 3a true
fc_lif2 up/up
20:0c:00:a0:98:4e:ba:14
cl01-02 3a true
lif1 up/up 172.16.21.31/24
cl01-01 a0a true
lif2 up/up 172.16.21.32/24
cl01-02 a0a true
4 entries were displayed.
cl01::>
Referring to the exhibit, a customer needs to move LIF "fc_lif1" to a new port.
Which three actions must be performed to accomplish this task? (Choose three.)
cl01::> net int show -vserver
svm1
(network interface show)
Logical Status Network
Current Current Is
Vserver Interface Admin/Oper
Address/Mask Node Port Home
----------- --------- ------
---- ------------------ -----
------- ------ ----
svm1
fc_lif1 up/up
20:0b:00:a0:98:4e:ba:14
cl01-01 3a true
fc_lif2 up/up
20:0c:00:a0:98:4e:ba:14
cl01-02 3a true
lif1 up/up 172.16.21.31/24
cl01-01 a0a true
lif2 up/up 172.16.21.32/24
cl01-02 a0a true
4 entries were displayed.
cl01::>
Referring to the exhibit, a customer needs to move LIF "fc_lif1" to a new port.
Which three actions must be performed to accomplish this task? (Choose three.)
Correct Answer: A,B,C
Vote an answer
Click the Exhibit button.
cl01-01::>vol show -vserver
svm1 -volume v_iscsi_exch01
Vserver Name: svm1
Volume Name: v_iscsi_exch01
Aggregate Name: a1_cl01_sas
Volume Size: 5 GB
Volume State: online
Volume Type: RW
Volume Style: flex
Available Size: 4.75GB
Filesystem Size: 5GB
Total User-Visible Size:
4.75 GB
Used Size: 144 KB
Used Percentage: 5%
Volume Nearly Full Treshold
Percent: 95%
Volume Full Treshold
Percent: 98%
Maximum Autosize (for
flexvolvs only): 6GB
(DEPRECATED) -Autosize
Increment (for flexvolvs
only): 256MB
Minimum Autosize: 5GB
Autosize Grow Threshold
Percentage: 85%
Autosize Shrink Threshold
Percentage: 50%
Autosize Mode: off
Autosize Enabled (for
flexvolvs only): false
Space Guarantee Style: volume
Space Guarantee in Effect:
true
Snapshot Directory Access
Enabled: true
Space Reserved for Snapshot
Copies: 5%
Snapshot Reserve Used: 0%
Snapshot Policy: none
Node name: cl01-01
Reserved Space for
Overwrites: 0B
Fractional Reserve: 100%
Primary Space Management
Strategy: volume_grow
Total Physical Used Size:
144KB
Physical Used Percentage: 0%
A customer has a volume with the configuration shown in the exhibit.
What will happen if the volume vs_iscsi_exch01 reaches 85% used?
cl01-01::>vol show -vserver
svm1 -volume v_iscsi_exch01
Vserver Name: svm1
Volume Name: v_iscsi_exch01
Aggregate Name: a1_cl01_sas
Volume Size: 5 GB
Volume State: online
Volume Type: RW
Volume Style: flex
Available Size: 4.75GB
Filesystem Size: 5GB
Total User-Visible Size:
4.75 GB
Used Size: 144 KB
Used Percentage: 5%
Volume Nearly Full Treshold
Percent: 95%
Volume Full Treshold
Percent: 98%
Maximum Autosize (for
flexvolvs only): 6GB
(DEPRECATED) -Autosize
Increment (for flexvolvs
only): 256MB
Minimum Autosize: 5GB
Autosize Grow Threshold
Percentage: 85%
Autosize Shrink Threshold
Percentage: 50%
Autosize Mode: off
Autosize Enabled (for
flexvolvs only): false
Space Guarantee Style: volume
Space Guarantee in Effect:
true
Snapshot Directory Access
Enabled: true
Space Reserved for Snapshot
Copies: 5%
Snapshot Reserve Used: 0%
Snapshot Policy: none
Node name: cl01-01
Reserved Space for
Overwrites: 0B
Fractional Reserve: 100%
Primary Space Management
Strategy: volume_grow
Total Physical Used Size:
144KB
Physical Used Percentage: 0%
A customer has a volume with the configuration shown in the exhibit.
What will happen if the volume vs_iscsi_exch01 reaches 85% used?
Correct Answer: A
Vote an answer
Click the Exhibit button.
After mapping the LUN on the cluster, you are not able to see in on the Windows 2012 host.
cl01::>igroup show -instance
Vserver Name: svm1
Igroup Name: ig1-win
Protocol: iscsi
OS Type: Windows
Portset Binding Igroup: -
Igroup UUID: 358338ba-cfd6-
11df-a9ab-123478563412
Initiators: iqn.1991-
05.com.microsoft: host1 (not
logged in)
Referring to the exhibit, what is the problem?
After mapping the LUN on the cluster, you are not able to see in on the Windows 2012 host.
cl01::>igroup show -instance
Vserver Name: svm1
Igroup Name: ig1-win
Protocol: iscsi
OS Type: Windows
Portset Binding Igroup: -
Igroup UUID: 358338ba-cfd6-
11df-a9ab-123478563412
Initiators: iqn.1991-
05.com.microsoft: host1 (not
logged in)
Referring to the exhibit, what is the problem?
Correct Answer: C
Vote an answer
Which two flags would you use to enable NetApp thin provisioning on a LUN? (Choose two.)
Correct Answer: A,D
Vote an answer
An administrator wants to provide isolation among physical devices connected to the same FCP fabric. Which Cisco
switch feature accomplishes this task?
switch feature accomplishes this task?
Correct Answer: A
Vote an answer
Explanation: Only visible for FreeCram members. You can sign-up / login (it's free).
Which command enables the FC protocol on clustered Data ONTAP?
Correct Answer: D
Vote an answer
Explanation: Only visible for FreeCram members. You can sign-up / login (it's free).
You configure space-reserved LUNs on thick-provisioned volumes, and you want to guarantee overwrites.
How would you accomplish this task?
How would you accomplish this task?
Correct Answer: B
Vote an answer
Explanation: Only visible for FreeCram members. You can sign-up / login (it's free).
Click the Exhibit button.
Referring to the exhibit, which entry is appropriate to add to a zone on the FC switch?

Referring to the exhibit, which entry is appropriate to add to a zone on the FC switch?

Correct Answer: D
Vote an answer