Huawei.H12-411.v2020-02-12.q50

Exam Code:H12-411
Exam Name:HCIA-Data Center Facility V1.0
Certification Provider:Huawei
Free Question Number:50
Version:v2020-02-12
Rating:
# of views:201
# of Questions views:1462
Start Practice Test

Valid H12-411 Dumps shared by PrepAwayExam.com for Helping Passing H12-411 Exam! PrepAwayExam.com now offer the newest H12-411 exam dumps, the PrepAwayExam.com H12-411 exam questions have been updated and answers have been corrected get the newest PrepAwayExam.com H12-411 dumps with Test Engine here:

Access Premium Version
(185 Q&As Dumps, 40%OFF Special Discount: freecram)

LEAVE A REPLY

Your email address will not be published. Required fields are marked *

Exam Question List
Question 1: The function of the fire protection system is automatically ...
Question 2: In a data center use fire water and foam extinguishing syste...
Question 3: Alarms of the dynamic environment monitoring system usually ...
Question 4: ACB circuit breakers are mainly used for IT load front-end; ...
Question 5: Users can use the () function to assign personnel to trouble...
Question 6: When mains input range of voltage: 150-260VAC, frequency: 45...
Question 7: Huawei NetEco monitoring system does not support remote door...
Question 8: () is used to ensure that the extinguishing agent is sprayed...
Question 9: There are three different categories of earthing (TN, TT and...
Question 10: What types does Dual power switch ATS switch according to th...
Question 11: Which of the following is not part of the chilled water air ...
Question 12: The main monitoring objects of data center room monitoring s...
Question 13: According to the concentration degree of equipment, air cond...
Question 14: In the process of construction, carry out the debris splash ...
Question 15: RER (Renewable Energy Ratio) is used to measure data center ...
Question 16: Use RS485 communication, the maximum communication distance ...
Question 17: Which of the following start then the alarm emits a strong s...
Question 18: The principle of evaporator is to convert refrigerant from l...
Question 19: Dynamic environment monitoring system only has secondary arc...
Question 20: Huawei NetEco monitoring system supports hierarchical networ...
Question 21: Which of the following is not a basic function of a low-volt...
Question 22: MCB circuit breaker can be divided into B, C, D, Z, K class ...
Question 23: ATS Dual Power Automatic Transfer Switch can achieve the swi...
Question 24: Which of the following outdoor modles belongs to double fan?...
Question 25: Dynamic environment monitoring system, can be used to store ...
Question 26: Computer room fire protection system mainly consists of () s...
Question 27: A UPS capacity is 200KVA with output power factor is 0.9, th...
Question 28: Huawei dynamic environment monitoring system's components ha...
Question 29: Dynamic environment monitoring system can be applied to () s...
Question 30: What throttle devices does Huawei air-cooled precision air c...
Question 31: Which of the following does not belong to the four major com...
Question 32: The STS Static Transfer Switch enables switching between dif...
Question 33: UPS can clean electricity input, output stable exchange, to ...
Question 34: The principle of the condenser is to cool and release the hi...
Question 35: The following () circuit breakers are typically low voltage ...
Question 36: Which fire extinguishing agent is mainly used in data center...
Question 37: The end of lead-acid battery discharge, the vottage drop, po...
Question 38: In the battery installation process, the use of high-voltage...
Question 39: During the construction process, which should be used in cor...
Question 40: Generally there are two kinds for VAV ventilation, one is th...
Question 41: Access control system can only set whether the user can open...
Question 42: Air conditioning has three major indicators; the three major...
Question 43: Which of the following description about sending back to sen...
Question 44: The features of UPS are (). (Multiple Choice)...
Question 45: Leakage current protection device is based on the current ex...
Question 46: Under the same load conditions, the backup time of the UPS i...
Question 47: Data center energy consumption mainly comes from the ring eq...
Question 48: Common communication equipment ways have RS232, RS485, FE, e...
Question 49: Gas fire protection systems are fire extinguishing systems t...
Question 50: There are three different categories of earthing (TN, TT and...