NEW QUESTION # 81
UPS5000 -E (25-75kVA) power module is only 2U in height.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 82
If the customer has high requirements for the availability of the management system and requires that the normal use of the system should not be affected by single-point hardware failures, the NetEco management system can provide which of the following high-availability solution of dual-machine mutual backup?

  • A. 2 servers + 1 disk array + 1 switch
  • B. None of the above is correct
  • C. 1 server + 1 disk array + 2 switches
  • D. 2 servers + 2 disk arrays + 3 switches

Answer: D


NEW QUESTION # 83
UPS5000-A system, which of the following battery configurations is unreasonable?

  • A. 37 12V batteries
  • B. 40 12V batteries
  • C. 32 12V batteries
  • D. 42 12V batteries

Answer: A


NEW QUESTION # 84
The water inlet slope of the fan coil condensate tray should be no less than?

  • A. 0.05
  • B. 0.02
  • C. 0.01
  • D. 0.1

Answer: B


NEW QUESTION # 85
UPS500-A-400/500K can support a maximum of () parallel connections and has good scalability.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 86
In the UPS5000 configuration, different battery solutions can be obtained by adjusting the number of battery groups and the number of battery cells in a single group.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 87
What is the model of the row-level air conditioner of Fusionmodule2000?

  • A. ECC800
  • B. NetCo15000
  • C. PDU8000
  • D. UPS5000

Answer: B


NEW QUESTION # 88
Three-proof paint coating can significantly reduce the failure rate of UPS in harsh environments such as salt spray, dust, high temperature and humidity, and ensure its service life in harsh environments.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 89
Which of the following communication functions does UPS5000-E include? (Multiple choice)

  • A. RS485
  • B. RS232
  • C. Dry contact card
  • D. SNMP

Answer: A,C,D


NEW QUESTION # 90
The backup time of UPS system is generally within 30 minutes. It is more reasonable to use the constant current method to calculate the battery capacity.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 91
When using ModBUS to remotely manage UPS500-E, which option should be selected?

  • A. RS232 to USB interface
  • B. No
  • C. ModBUS card

Answer: B


NEW QUESTION # 92
FusionModule2000 integrated UPS has two configurations: single MCCB and dual ATS.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 93
One indoor unit of Huawei Netcol air-cooled air conditioner can correspond to multiple outdoor units.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 94
NetEco6000 management system supports virtualization deployment and adapts to the future cloud computing rhythm.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 95
What is the channel width of Huawei Fusionmodule2000?

  • A. 1000mm
  • B. 1100mm
  • C. 1200mm
  • D. 1300mm

Answer: C


NEW QUESTION # 96
Which is the correct description of UPS5000-E bypass overload capacity?

  • A. 1000% overload for 100ms
  • B. 125% overload for 10 minutes
  • C. 135% long-term overload
  • D. 125% overload for 60 minutes

Answer: C


NEW QUESTION # 97
What are the dimensions of Huawei cabinets? (Multiple choice)

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A,B,C,D


NEW QUESTION # 98
What kind of inlet and outlet wiring methods can be realized by FusionModule2000 precision power distribution cabinet? (Multiple choice)

  • A. Up-line in and down-line out
  • B. Lower inlet and upper outlet
  • C. Inlet and outlet
  • D. Inlet and outlet

Answer: A,B,C,D


NEW QUESTION # 99
NETECO's basic functions include? (Multiple choice)

  • A. Access Control Management
  • B. Video Management
  • C. Report Management
  • D. User Management

Answer: A,B,C,D


NEW QUESTION # 100
How many poles of circuit breaker are generally used for the external maintenance bypass of UPS system?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B