Cisco 300-610 exam is designed for professionals who want to validate their skills in designing Cisco data center infrastructure. Designing Cisco Data Center Infrastructure certification exam covers a range of topics related to data center infrastructure design, including data center networking, storage networking, compute networking, automation, and security. Passing 300-610 exam is a crucial step for professionals who want to advance their career in the field of data center infrastructure design.
NEW QUESTION # 27
Drag and drop the Cisco Nexus 7000 Series Switch resources from the left onto the correct groups on the right.
Answer:
Explanation:

NEW QUESTION # 28
Which two naming formats identify target or initiator iSCSI nodes? (Choose two.)
- A. IQN
- B. WWPN
- C. OUI
- D. EUI
- E. WWN
Answer: A,E
Explanation:
https://docs.vmware.com/en/VMware-vSphere/5.5/com.vmware.vsphere.storage.doc/GUID-686D92B6-A2B2-4944-8718-F1B74F6A2C53.html
NEW QUESTION # 29
An engineer working for a private telecommunication company with an employee ID 4419 90 979 is installing a pair of Nexus 7000 Series Switches and must deploy the solution with these requirements
* The environment must be separated for test and production purposes
* The separation should include control, data and management plane with fault domain isolation and improved security
* The test environment needs only F2 series line cards and a maximum of 256 VLANs Which set of actions meets these requirements?
- A. Use VRF for each of the environments
Configure limit-resource module-type functionality for the test VDC.
Enable module-type for the VRF - B. Use VRF faQUMIife environments
Configure allow feature set for both VRFs
Enable limit-resource vlan minimum for the test VRF - C. Use VDC for each of the environments
Configure allow feature set for both VRFs
Enable limit-resource vlan maximum for the test VRF - D. Use VDC for each of the environments
Configure limit-resource module-type functionality for the test VDC
Enable limit resource vlan for the test VDC.
Answer: D
NEW QUESTION # 30
Which two types of service profile templates does Cisco UCS support? (Choose two.)
- A. connected
- B. updating
- C. temporary
- D. permanent
- E. initial
Answer: B,E
Explanation:
Section: Automation Design
Explanation/Reference: https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/ UCSM_GUI_Configuration_Guide_141_chapter28.html#concept_C9D27CE2AA1245EA976DAA79F5BC6808
NEW QUESTION # 31
An engineer is experiencing performance issues on a cisco UCS blade server. The B-series blade server contains four CPUs, most of which are idle. The engineer notices that the CPU is suffering from too many requests sent by the NIC. Additionally, the number of queues appears to be insufficient and only a single CPU is processing the network traffic. Which policy must be used to alleviate these issues?
- A. vNIC placement
- B. Ethernet adapter
- C. LAN connectivity
- D. Dynamic vNIC connection
Answer: B
Explanation:
https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter19.html
Ethernet adapter policy is the only policy that is having configuration that is related to CPU.
NEW QUESTION # 32
An engineer finishes the initial set up of a VXLAN EVPN network. The engineer is asked to plan for connectivity that supports redundancy and extends multiple virtual routing and forwarding domains. The requirement is to use the same default gateway addressing across all leaf switches that belong to the VXLAN network. Which two solution must be used to meet these requirements? (Choose two)
- A. VRF-lite
- B. spanning tree protocol
- C. DC interconnect
- D. Inter-site network
- E. Distributed anycast gateway
Answer: C,E
Explanation:
https://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst9300/software/release/16-12/configuration_guide/vxlan/b_1612_bgp_evpn_vxlan_9300_cg/configuring_evpn_vxlan_anycast_gateway.html
https://www.cisco.com/c/en/us/products/collateral/switches/nexus-9000-series-switches/white-paper-c11-739942.html


NEW QUESTION # 33
Where does Cisco UCS handle Fibre Channel traffic failover?
- A. on a Cisco UCS Fabric Interconnect ASIC in Fibre Channel switching mode
- B. on the host, by using multipathing software
- C. in the hardware on any Cisco UCS VIC adapter
- D. in the hardware on the Cisco UCS VIC 12xx adapter or later
Answer: B
Explanation:
Typically, host software - such as NIC teaming for Ethernet and EMC PowerPath or multipath I/O (MPIO) for Fibre Channel - provides failover across the two fabrics (Figure 4).
https://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/unified- computing/whitepaper_c11-701962.html
NEW QUESTION # 34
A network architect proposes a distinct Fibre Channel fabric to be used for a Cisco UCS blade server that hosts critical applications.
Which action should be implemented for the Fibre Channel traffic from the vHBA of this server to pass through the I/O Module in the Cisco UCS chassis to a specified uplink Fibre Channel port?
- A. Enable Persistent Binding in the vHBA policy.
- B. Update the applied global QoS policy.
- C. Update the applied Fibre Channel adapter policy.
- D. Include a SAN pin group in the vHBA policy.
Answer: D
Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User- Guides/Storage-Mgmt/3-
2/b_UCSM_GUI_Storage_Management_Guide_3_2/b_UCSM_GUI_Storage_Management_Guid e_3_ 2_chapter_0110.pdf
NEW QUESTION # 35
Which Ethernet to Cisco Fabric Interconnect connectivity configuration is supported when FCoE is implemented?
- A. vPC that has unified uplinks
- B. cross-connections with pinning
- C. VSS that has unified uplinks
- D. Ethernet and unified ports on the same port channel
Answer: A
Explanation:
Section: Storage Network Design
Explanation/Reference: https://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-manager/116188- configure-fcoe-00.html#anc11
NEW QUESTION # 36
A company has added a new FCoE storage array to increase the performance of datastore access for end users. This storage array is directly connected to the Cisco Nexus 5672UP switches using four 10G port-channel interfaces. After deployment, the end users fail to access the datastore compared to the older solution. A network engineer verified the port-channel interface and finds that the congestion occurs when PFC frames are generated at the FCoE ingress interface. Which action must be taken to resolve the congestion issue?
- A. Reserve bandwidth for FCoE VLAN on the port-channel interface connected with storage.
- B. Increase the queuing buffer in the port-channel interface connected to the storage array.
- C. Enable the FCoE class in QoS on Cisco Nexus 5672UP switches.
- D. Add an additional FCoE VLAN to the SAN network.
Answer: B
NEW QUESTION # 37
An engineer must build a VXLAN flood-and-learn network. The customer requires the solution to be based on the IETF documented practice in RFC 7348. The solution must use broadcast, unknown unicast, and multicast (BUM) and include the efficient BUM and short BUM replication modes that use only shared trees.
Which technology meets these requirements?
- A. Bidirectional PIM
- B. MVPN
- C. PIM sparse mode
- D. PIM SSM
Answer: C
Explanation:
Reference:
flexpod_esxi70_vxlan_evpn_design.html
NEW QUESTION # 38
Which two naming formats identify target or initiator iSCSI nodes? (Choose two.)
- A. IQN
- B. WWPN
- C. OUI
- D. EUI
- E. WWN
Answer: A,E
NEW QUESTION # 39
What must be configured in Cisco Intersight when Enum is selected as the data type in a workflow input?
- A. Secure
- B. Regex
- C. Object Selector
- D. Widget type
Answer: D
NEW QUESTION # 40
A network consultant evaluates the Cisco UCS Fabric Interconnect SAN configuration, which must meet these requirements:
All traffic must pass over the upstream device for switching and domain IDs must be preserved in the fabric.
Each server should be pinned to one designated upstream interface and for the traffic to pass through the pinned port.
Which Fabric Interconnect SAN operational mode meets these requirements?
- A. switch
- B. NPIV
- C. end host
- D. Fibre Channel
Answer: C
NEW QUESTION # 41
Refer to the exhibit. A Cisco engineer is configuring a customer scenario with 2 x MDS 9000 switches 24 x UCS B200M6 blade servers. UCS 64S4 Fabric Interconnect in end-host mode and 3 x UCS 5108 server chassis with 2408 Fabric Extenders The engineer installs 6 x SQL Server 2019 on all blades and then notices that there are read and write latencies What is the best way to balance the utilization across the shared ports?
- A. Disable restrictions on oversubscription ratios
- B. Change the assigned speed to 8 Gbps Auto.
- C. Enable "Only dedicate rate mode
- D. Set 4 Gbps performance buffers
Answer: A
Explanation:
Reference:
When restrictions on oversubscription ratios are disabled, the bandwidth allocation among the shared ports is proportionate to the configured speed. (If the configured speed is auto, then bandwidth is allocated assuming a speed of 4 Gbps.) For example, if you have three shared ports configured at 1, 2, and 4 Gbps, then the allocated bandwidth ratio is 1:2:4. In Cisco SAN-OS Release 3.0 and later (or when restrictions on oversubscription ratios are enabled), port bandwidths are allocated in equal proportions, regardless of port speed, so, the bandwidth allocation for the same three ports mentioned in the example would be 1:1:1.
NEW QUESTION # 42
......